Module Breakage Tester
Meet the module breakage tester requirement in the MST32 clause of IEC61730 standard.
l Catching or releasing impactor bag could be controlled.
l Including protective nets on both sides to protect against secondary impact hazards.
l Motor is used to lift the impactor bag and the height could be controlled.
l Include a variety of fixtures, module vertically mounted in the experimental frame.
l The frame is securely bolted at the corners to minimize twisting during impact. It also is bolted to the floor to prevent movement during impact testing.
l Wireless control function.
Item  | 
  | 
Diameter and height ratio of the impactor bag  | 1:1.5~1:1.4  | 
Distance between the module surface and the bag.  | ≤13mm  | 
Distance between the module center and the bag.  | ≤50mm  | 
Impact height  | 300,450,600,750,900,1220mm  | 
Support size  | 100*200mm  | 
Bag weight  | 45.5 kg±0.5kg  | 
Remote control distance  | ≤10m  | 
kinetic energy  | 542J when swung through a 1,2m vertical drop.  | 
Material in the impactor  | Lead pellet  | 
Diameter of the pellet  | 2,5 mm to 3,0 mm  | 
Section size of steel channel  | 360mm*100mm  | 